DC402 Air Conditioning Recharge Kit for Duracool / Multicool / Climapure Canisters
      DC402 Air Conditioning Recharge Kit for Duracool / Multicool / Climapure Canisters

      DC402 Air Conditioning Recharge Kit for Duracool / Multicool / Climapure Canisters

      490404
      €29.90
      Tax included

      Of which €0.03 eco-tax

      (4/5) out of 71 total ratings
      Read the reviews
      In Stock

      The DC402 air conditioning recharge kit is the essential professional tool for efficiently recharging vehicle air conditioning systems with Duracool, Multicool and Climapure canisters. Equipped with a 1/2 ACME threaded valve and two fittings (R134a and R12 low pressure), this kit adapts to the vast majority of vehicles on the market.

      Complete solution for professionals and demanding individuals, it guarantees precise and safe recharging of your automotive air conditioning with Duracool ecological refrigerant gases.

      Quantity:
      In Stock 300 Available
      • Safety guaranteesSafety guarantees100% secure payment
      • Shipping PolicyShipping PolicyResponsive and attentive after-sales service
      • Returns PolicyReturns PolicyFast and secure delivery

      DC402 Duracool Air Conditioning Recharge Kit (Reference: 490404): The professional reference tool for recharging automotive air conditioning systems with Duracool, Multicool and Climapure ecological refrigerant gas canisters. This complete kit integrates all the necessary elements for a quick, precise and safe intervention on the majority of vehicles on the market.

       


       

      Applications and Areas of Use

      The DC402 kit is designed for professional garage owners, mechanics specialized in automotive air conditioning and informed individuals wishing to perform their own vehicle air conditioning maintenance. It is perfectly suited for recharging refrigeration circuits of passenger cars, light commercial vehicles, vans and certain commercial vehicles.

      This kit works exclusively with Duracool refrigerant gas canisters, ecological alternatives to traditional gases R12, R134a, R1234yf, R22, R502, R407, R404a, R410a and R32. It enables emergency on-site or workshop intervention to address minor leaks and quickly restore a failing air conditioning system to service.

       


       

      Technical Design and Compatibility

      The heart of this kit is based on a high-quality valve with 1/2 ACME threading, the universal standard for connecting to refrigerant gas canisters. This standardized threading ensures perfect sealing and optimal safety when handling pressurized fluids.

      The kit includes two specific fittings to cover all automotive standards: an R134a low-pressure fitting (majority standard since the 1990s) and an R12 low-pressure fitting (older and classic vehicles). These fittings allow direct connection to the low-pressure service ports of air conditioning circuits, the preferred access point for safe recharging.

      Important: certain manufacturers like Renault only equip their vehicles with a single high-pressure fitting, requiring a specific adapter not included in this standard kit.

       


       

      Operating Procedure and Safety

      Using the DC402 kit requires strict adherence to safety procedures related to handling refrigeration fluids. Before any intervention, it is essential to ensure the engine is stopped and cooled, wear personal protective equipment (gloves, safety glasses) and work in a well-ventilated area.

      The procedure begins with identifying the vehicle's low-pressure fitting, generally located on the return line between the evaporator and compressor. Once the appropriate fitting is selected and connected, the Duracool canister screws onto the kit's 1/2 ACME valve.

      Gas addition must be performed with the engine running and air conditioning activated to allow fluid circulation in the circuit. Recharging stops when the air outlet temperature reaches nominal values or according to the vehicle manufacturer's specifications.

       


       

      Expert Tips and Usage Optimization

      To maximize the effectiveness of the DC402 kit, it is recommended to complement it with diagnostic tools such as a pressure gauge or laser thermometer to monitor operating pressures and temperatures. Adding an electronic leak detector also allows identification of leak sources before recharging.

      Duracool canisters being ecological gases, they have the advantage of being compatible with mineral and synthetic oils already present in circuits. However, for interventions on old or severely degraded systems, adding refrigeration oil and leak sealant may be necessary.

      Professional tip: performing recharging in small successive quantities (maximum 1/3 canister per session) allows better process control and prevents circuit overcharging. Always clean fittings after use and protect them with caps to maintain their sealing.

       


       

      Technical Specifications

      DetailsSpecifications
      Reference490404
      BrandDuracool
      Valve Type1/2 ACME Threading
      Included FittingsR134a low pressure + R12 low pressure
      Canister CompatibilityDuracool, Multicool, Climapure
      ApplicationAutomotive air conditioning
      Connection TypeLow pressure fittings only
      UsageProfessional and consumer
      490404
      300 Items

      Specific references

      EAN13
      3760235768591

      Customers who bought this product also bought: